Proactive alerts provide health-based alerts for the following Tealeaf components: Canister server, data services, and CX Passive Capture Application server. You can use TMS to configure proactive alerts for Canister servers, data services, and PCA servers.
- Parameter name for which the alert is generated
- Current value of the parameter
- Threshold value that is configured for the parameter
- Component name for which the parameter is configured
Keep the following points in mind when you configure proactive alerts:
- If a Tealeaf component is scheduled to be shut down for maintenance, disable proactive alerts for the component.
- If proactive alerts feature for a component is disabled for its maintenance, manually enable proactive alerts for the component after the component is up and running, and restart the TMS server.
- If Canister servers or CX PCA servers are added or removed, or if any threshold values have changed, manually change the configuration of proactive alerts for the component, and restart the TMS server.
You can enable or disable proactive alerts in the Proactive Alerts Configuration window. Once disabled, proactive alerts are not generated for any component even if you configured an alert condition for the component.
Complete the following steps to configure Canister servers, data services, and CX PCA servers to receive proactive alerts.
- On the TMS home page, go to the Worldview tab.
- Expand your master server and then expand the Tealeaf Management Server node.
- Click the Proactive Alerts Configuration MasterServerName link.
- Ensure that the Turn on Proactive Alerts check box is selected. If you want to turn off the Proactive Alerts feature, clear the Turn on Proactive Alerts check box.
Important: If you configured proactive alerts for any component, and if you clear the Turn on Proactive Alerts check box, proactive alerts are not generated for any component.
- In the Global PA Rules area, click Edit. The PA Global Edit window opens. Refer to the following table to add information for email alerts:
Table 1. Information about the fields in the PA Global Edit window This is a two-columned table, where the first column lists the field name in the PA Global Edit window, and the second column describes the field.
In the following field Enter the following information SMTP Server SMTP server name SMTP Port SMTP port Email from The name that appears as the sender of proactive alerts Email to The email address of the recipient of proactive alerts You can add multiple recipients by using a comma to separate the addresses.
Snooze Add the time (in minutes) for a pause between two consecutive proactive alerts. The snooze time that you configure is applicable for all components. - Complete the tasks in the following table to add a Canister server, data service, or PCA server for configuring proactive alerts:
Table 2. Adding a Canister, data service, or PCA This is a two-columned table with the name of the component for configuring proactive alerts in one column, and the steps to add the component for proactive alerts in the second column.
To add... Complete these tasks in the Proactive Alerts Configuration window... Canister - In the Canister Server Rules area, click Add Canister.
- In the Canister Servers list, select a Canister.
- In the Port field, enter the Canister port and click OK.
Data service - In the Data Services Rules area, click Add Data Service.
- In the Data Service Servers list, select a data service.
- In the Port field, enter the data service port and click OK.
PCA - In the PCA Rules area, click Add PCA.
- In the PCA Server list, enter the host name, which is the fully qualified domain name (FQDN), of the PCA server.
- In the Port field, enter the PCA port and click OK.
Copying proactive expressions from one server to another
You can use TMS to copy proactive expressions from one server to another.
Use the following procedure to copy proactive expressions from one server to another.
- In TMS, from the WorldView page, expand the twistie for Tealeaf Management Server.
- Select Proactive Alerts Configuration.
- Select Copy Expressions and make your selections from the dialog.
- From the Copy From field, select the sever you are copying the expression from.
- From the Expressions list, select the proactive expressions to copy.
- From the Copy To field, select the server that you want to copy the proactive expression to.
- Click OK to copy the selected expression to the server.
If the server you are copying the expression to is configured for Proactive alerts, the copied expression overwrites the existing expression on that server.
If server is not configured for Proactive alerts, then the server is added to Proactive alert configuration when you copy over the expression.
Suppressing proactive alerts from triggering
You can impose a blackout for Proactive alerts. A blackout is a user-defined period of time, during which the Proactive alert is prevented from triggering.
You can use blackouts to avoid generating skewed alert values that might be generated because of system backups, restarts, and other activities.
Use the following procedure to configure a blackout for a Proactive alert.
- In TMS, from the WorldView page, expand the twistie for Tealeaf Management Server.
- Select Proactive Alerts Configuration .
- Select View/Edit
- From the Proactive Alerts Configuration dialog, you can set the blackout interval:
- Click Configure Canister and select Blackouts.
- Click Configure Data Service and select Blackouts.
- Click Configure Data Collector and select Blackouts.
- To configure a common blackout for multiple days, in the Edit Alert window, select the days and click the Enable Common Blackout check box.
- Save your changes.
Adding alert conditions
Use the Proactive Alerts Configuration window to add proactive alert conditions for Tealeaf components.
Complete the following steps to add proactive alert conditions.
- On the TMS home page, go to the Worldview tab.
- Expand your master server and then expand the Tealeaf Management Server node.
- Click the Proactive Alerts Configuration MasterServerName link.
- Ensure that the Turn on Proactive Alerts check box is selected. If you want to turn off the Proactive Alerts feature, clear the Turn on Proactive Alerts check box.
Important: If you have configured proactive alerts for any component, and if you clear the Turn on Proactive Alerts check box, proactive alerts are not generated for any component.
- Complete the tasks in the following table to add an alert condition for a Canister, data service, or PCA:
Note: An alert condition is an expression, and can have one of the following operators:
- <
- >
- =
Table 3. Adding an alert threshold This is a two-columned table with the name of the component for configuring an alert condition in one column, and the steps to add the alert condition in the second column.
To add an alert for... Complete these tasks in the Proactive Alerts Configuration window... Canister - In the Canister Server Rules area, click Add Canister.
- In the Canister Servers field, select a Canister server.
- In the Port field, enter the port number.
- Click OK to add the Canister server in the Protective Alerts Configuration window.
Data service - In the Data Service Rules area, click Add Data Service.
- In the Data Service Servers field, select a Data Service server.
- In the Port field, enter the port number.
- Click OK to add the Data Service in the Protective Alerts Configuration window.
PCA - In the PCA Rules area, click Add PCA.
- In the PCA Server field, select a PCA server.
- In the Port field, enter the port number.
- Click OK to add the PCA server in the Protective Alerts Configuration window.
Data Collector - In the Data Collector Rules area, click Add Data Collector.
- In the Data Collector Servers field, select a Data Collector server.
- In the Port field, enter the port number. The default port number is 23000.
- Click OK to add the Data Collector server in the Protective Alerts Configuration window.
- Click Save.
- Restart the TMS server.
Note: Configuration for proactive alerts is not effective till the TMS server is restarted.
Editing alert conditions
Use the Proactive Alerts Configuration window to edit proactive alert conditions for Tealeaf components.
Complete the following steps to edit proactive alert conditions.
- On the TMS home page, go to the Worldview tab.
- Expand your master server and then expand the Tealeaf Management Server node.
- Click the Proactive Alerts Configuration MasterServerName link. The Proactive Alerts Configuration window opens.
- Ensure that the Turn on Proactive Alerts check box is selected. If you want to turn off the Proactive Alerts feature, clear the Turn on Proactive Alerts check box.
Important: If you have configured proactive alerts for any component, and if you clear the Turn on Proactive Alerts check box, proactive alerts are not generated for any component.
- Complete the tasks in the following table to edit an alert condition for a Canister, data service, or PCA:
Note: An alert condition is an expression, and can have one of the following operators:
- <
- >
- =
Table 4. Adding an alert threshold This is a two-columned table with the name of the component editing an alert expression in one column, and the steps to edit the alert expression in the second column.
To edit an alert for... Complete these tasks... Canister You can edit an expression from the Canister Edit window. - In the Canister Server Rules area, click Edit against a Canister server.
- In the Canister Expression Edit field, select an expression and click Edit. The Canister Expression Edit window opens.
- In the Operators field, select an operator for the expression.
- In the Threshold field, change the value of the expression, and click OK.
Data service You can edit an expression from the Data Service Edit window. - In the Data Service Rules area, click Edit against a data service.
- In the Data Service Expression Edit field, select an expression and click Edit. The Data Service Expression Edit window opens.
- In the Operators field, select an operator for the expression.
- In the Threshold field, change the value of the expression, and click OK.
PCA You can edit an expression from the PCA Edit window. - In the PCA Rules area, click Edit against a PCA server.
- In the Expressions field, select an expression and click Edit. The PCA Expression Edit window opens.
- In the Operators field, select an operator for the expression.
- In the Threshold field, change the value of the expression.
- Select or clear the Alert on SSL not getting decrypted check box as required.
- Select or clear the Alert on aged connection check box as required.
- In the Repetition Count field, edit the number of consecutive times that the PCA reaches a threshold, after which you receive an email alert, and click OK.
Note: This field is applicable only for the CPA Usage and Dropped Hits thresholds.
Data Collector You can edit an expression from the Data Collector Edit window. - In the Data Collector Rules area, click Edit against a Data Collector server.
- Select one or all of the following check boxes:
- Alert on lagging Fact Aggregation
- Alert on lagging Dimension Extraction
- Alert on lagging Data Collection
- In the Port field, change the port number, and click OK. The default port number is 23000.
- Click Save.
- Restart the TMS server.